Context: the project archive (KXKM_Batterie_Parallelator-main) had no git history locally; a fresh repository is needed to host it on git.saillant.cc (electron/KXKM_Batterie_Parallelator). Approach: initialize a new repo on branch main, stage the archive content, and harden .gitignore before the first commit. Changes: - Import the full project tree: firmware/, firmware-idf/, firmware-rs/, iosApp/, kxkm-bmu-app/, kxkm-api/, hardware/, docs/, specs/, scripts/, models/, tests/ - Keep project dotfiles tracked despite the trailing '.*' ignore rule: .github/, .claude/, .superpowers/, .gitattributes, .markdownlint.json - Extend .gitignore: firmware/src/credentials.h (local secrets, template kept), kxkm-bmu-app/**/build/ (66 MB compiled iOS framework), .remember/ (session data) Impact: the project can now be maintained on the self-hosted Gitea forge with a clean, secret-free initial history.
272 lines
9.1 KiB
Markdown
272 lines
9.1 KiB
Markdown
# Plan de validation — KXKM Batterie Parallelator
|
||
|
||
> Kill_LIFE gate: S3
|
||
> Version: 1.0 (2026-03-25)
|
||
|
||
---
|
||
|
||
## Vue d'ensemble
|
||
|
||
Trois niveaux de validation, du plus léger au plus complet :
|
||
|
||
| Niveau | Nom | Outillage | Couverture |
|
||
|--------|-----|-----------|------------|
|
||
| **L1** | Tests unitaires natifs | `pio test -e native` (pas d'ESP32) | Logique protection pure (F03–F08) |
|
||
| **L2** | Simulation étendue | `g++ sim_s3.cpp && ./sim_s3` (pas d'ESP32) | Tous scénarios firmware F01–F08, F11 |
|
||
| **L3** | Banc hardware | BMU + alimentation programmable + ESP32 | Couverture complète F01–F11 |
|
||
|
||
Statut actuel : **L1 ✅ L2 ✅ L3 ⬜**
|
||
|
||
---
|
||
|
||
## L1 — Tests unitaires natifs (`pio test -e native`)
|
||
|
||
Fichier : `firmware/test/test_protection/test_protection.cpp`
|
||
|
||
| ID | Test | Résultat |
|
||
|----|------|----------|
|
||
| U01 | `test_undervoltage_disconnects` | ✅ |
|
||
| U02 | `test_nominal_voltage_connects` | ✅ |
|
||
| U03 | `test_overvoltage_disconnects` | ✅ |
|
||
| U04 | `test_overcurrent_positive_disconnects` | ✅ |
|
||
| U05 | `test_overcurrent_negative_disconnects` | ✅ |
|
||
| U06 | `test_nominal_current_connects` | ✅ |
|
||
| U07 | `test_voltage_imbalance_disconnects` | ✅ |
|
||
| U08 | `test_voltage_imbalance_within_threshold_connects` | ✅ |
|
||
| U09 | `test_permanent_lock_above_max` | ✅ |
|
||
| U10 | `test_no_permanent_lock_at_max` | ✅ |
|
||
|
||
---
|
||
|
||
## L2 — Simulation étendue (`firmware/test/test_s3_sim/`)
|
||
|
||
Fichiers : `sim_s3.cpp` (scénarios S3) + `sim_validation.cpp` (validation étendue)
|
||
|
||
### Scénarios S3 de base
|
||
|
||
| ID | Scénario | Description | Résultat |
|
||
|----|----------|-------------|----------|
|
||
| S3-A | Déséquilibre tension | BAT1=27V BAT2=25V → coupure BAT2, remonte → reconnexion | ✅ |
|
||
| S3-B | Reconnexion auto | BAT2=22V → coupure → remonte → reconnexion immédiate (sw<5) | ✅ |
|
||
| S3-C | Verrouillage permanent | 5 cycles fault/normal → tempo 10s → 6e faute → lock | ✅ |
|
||
|
||
### Scénarios de validation étendue (`sim_validation.cpp`)
|
||
|
||
| ID | Scénario | Description | Résultat |
|
||
|----|----------|-------------|----------|
|
||
| TV01 | Seuil sous-tension exact | 24 000 mV = connexion autorisée ; 23 999 mV = coupure | ✅ |
|
||
| TV02 | Seuil sur-tension exact | 30 000 mV = connexion autorisée ; 30 001 mV = coupure | ✅ |
|
||
| TV03 | Sur-courant positif | +1.1 A → coupure ; +0.9 A → connexion | ✅ |
|
||
| TV04 | Sur-courant négatif | −1.1 A → coupure ; −0.9 A → connexion | ✅ |
|
||
| TV05 | Seuil déséquilibre exact | diff = 1.0 V → connexion ; diff = 1.001 V → coupure | ✅ |
|
||
| TV06 | 4 batteries, 1 en faute | BAT1–3 ok, BAT4=22V → seule BAT4 coupée, les autres ok | ✅ |
|
||
| TV07 | Temporisation 10 s précise | Au tick nb_switch=5 : tempo, pas de reconnexion avant 10 s | ✅ |
|
||
| TV08 | Faute courant + déséquilibre | Double faute sur même batterie → 1 seule incrémentation sw | ✅ |
|
||
|
||
---
|
||
|
||
## L3 — Banc hardware
|
||
|
||
### Matériel requis
|
||
|
||
| Quantité | Composant | Spec | Usage |
|
||
|----------|-----------|------|-------|
|
||
| 2 | Alimentation programmable | 0–35 V / 5 A min | Simule tensions batterie |
|
||
| 1 | Charge résistive ou électronique | 5–50 Ω / 5 W | Injection de courant test |
|
||
| 2 | Multimètre de précision | ±0.5% DC | Vérification mesures INA237 |
|
||
| 1 | BMU v1 ou v2 (PCB) | — | Carte sous test |
|
||
| 1 | ESP32 Wrover Kit (ou K32) | 16 MB flash | Microcontrôleur |
|
||
| 1 | Câble USB série | — | Moniteur 115200 baud |
|
||
| 1 | PC + PlatformIO | — | Flash + monitoring |
|
||
| 4 | Fils de mesure (banana) | ≥ 4 mm², 5 A | Connexion puissance |
|
||
|
||
### Montage du banc
|
||
|
||
```
|
||
[Alim 1]──────┐ [ESP32 / K32]
|
||
0–35V/5A │ │ I²C (GPIO32/33)
|
||
├──[INA237_0]──┤──[TCA9535_0]──[MOSFET 0]──[LED 🟢/🔴]
|
||
│ │
|
||
[Alim 2]──────┤
|
||
0–35V/5A ├──[INA237_1]──┤──[TCA9535_0]──[MOSFET 1]──[LED 🟢/🔴]
|
||
│ │
|
||
[Charge R]────┘ [USB série] → PC (115200 baud)
|
||
(optionnel)
|
||
```
|
||
|
||
> Commencer avec 2 batteries (Alim 1 + Alim 2) sur TCA9535_0.
|
||
> BMU v1 fabriqué = cible de test principale.
|
||
|
||
### Procédures de test hardware
|
||
|
||
#### TB01 — I²C scan (F01 F02 prérequis)
|
||
```
|
||
1. Flasher le firmware : pio run -e kxkm-v3-16MB --target upload
|
||
2. Ouvrir moniteur série : pio device monitor --baud 115200
|
||
3. Observer le scan I²C au démarrage
|
||
```
|
||
**Pass** : Toutes les adresses INA237 (0x40–) et TCA9535 (0x20–) attendues apparaissent.
|
||
**Fail** : Adresse manquante → vérifier câblage I²C, solder jumpers JP.
|
||
|
||
---
|
||
|
||
#### TB02 — Calibration mesure tension (F01)
|
||
```
|
||
1. Alim 1 → 27.00 V (réglé sur source)
|
||
2. Mesurer la tension en parallèle avec multimètre
|
||
3. Lire valeur INA237 sur moniteur série
|
||
```
|
||
**Pass** : Écart INA237 vs multimètre < ±0.5% (±135 mV sur 27 V).
|
||
|
||
---
|
||
|
||
#### TB03 — Calibration mesure courant (F02)
|
||
```
|
||
1. Alim 1 → 27.00 V, charge R = 27 Ω → courant théorique = 1.0 A
|
||
2. Mesurer courant avec pince ampèremétrique ou shunt externe
|
||
3. Lire valeur INA237 sur moniteur série
|
||
```
|
||
**Pass** : Écart INA237 vs référence < ±5% (±50 mA sur 1 A).
|
||
|
||
> Rappel : shunt = 2 mΩ (BMU v1/v2), plage INA237 = ±163.84 mV → max ~82 A.
|
||
|
||
---
|
||
|
||
#### TB04 — Test relais MOSFET (F03 F04 base)
|
||
```
|
||
1. Alim 1 → 27 V, vérifier LED verte allumée (batterie connectée)
|
||
2. Observer signal de commande TCA9535 (GPIO 0–3) avec oscilloscope ou LED de test
|
||
3. Baisser Alim 1 à 22 V
|
||
4. Attendre 500 ms (1 tick)
|
||
```
|
||
**Pass** : LED passe rouge, relais MOSFET ouvert (mesurer continuité ou Vout=0).
|
||
|
||
---
|
||
|
||
#### TB05 — Protection sous-tension (F04)
|
||
```
|
||
1. Alim 1 → 27 V (nominal)
|
||
2. Baisser progressivement jusqu'à 24.0 V → vérifier connexion maintenue
|
||
3. Baisser à 23.9 V → vérifier coupure
|
||
4. Remonter à 27 V → vérifier reconnexion (nb_switch=1 < 5)
|
||
```
|
||
**Pass** :
|
||
- 24.0 V → connecté
|
||
- 23.9 V → coupure dans les 500 ms suivant la lecture
|
||
- Retour 27 V → reconnexion dans les 500 ms
|
||
|
||
---
|
||
|
||
#### TB06 — Protection sur-tension (F03)
|
||
```
|
||
1. Alim 1 → 27 V
|
||
2. Monter à 30.0 V → connexion maintenue
|
||
3. Monter à 30.1 V → coupure attendue
|
||
4. Redescendre à 27 V → reconnexion
|
||
```
|
||
**Pass** : même logique que TB05.
|
||
|
||
---
|
||
|
||
#### TB07 — Protection sur-courant (F05)
|
||
```
|
||
1. Alim 1 → 27 V, charge variable
|
||
2. Charge légère (R=100Ω → ~270 mA) → connexion maintenue
|
||
3. Charge lourde (R=24Ω → ~1.1 A) → coupure attendue dans 500 ms
|
||
4. Couper charge → reconnexion
|
||
```
|
||
**Pass** : coupure à I > 1 A, connexion à I < 1 A.
|
||
**Note** : tester aussi courant négatif (retour de charge régénérative si dispo).
|
||
|
||
---
|
||
|
||
#### TB08 — Déséquilibre tension 2 batteries (F06)
|
||
```
|
||
1. Alim 1 → 27 V, Alim 2 → 25 V
|
||
2. Les deux connectées au démarrage
|
||
3. Attendre 1 tick (500 ms)
|
||
```
|
||
**Pass** :
|
||
- BAT2 déconnectée (LED rouge), BAT1 maintenue (LED verte)
|
||
- nb_switch(BAT2) inchangé (déséquilibre ne compte pas)
|
||
- Remonter Alim 2 à 27 V → BAT2 reconnectée dans 500 ms
|
||
|
||
---
|
||
|
||
#### TB09 — Reconnexion automatique & tempo (F07)
|
||
```
|
||
1. Provoquer 4 coupures manuelles sur BAT1 (sous-tension répétée)
|
||
2. À la 5e : observer message "too many cut off battery, try to reconnect in X s"
|
||
3. Mesurer durée avant reconnexion
|
||
```
|
||
**Pass** : reconnexion dans 10 s ± 1 s après la 5e coupure.
|
||
|
||
---
|
||
|
||
#### TB10 — Verrouillage permanent (F08)
|
||
```
|
||
1. Provoquer 6 coupures sur BAT1
|
||
2. Observer message "too many cut off battery, constant cut off"
|
||
3. Remonter tension à nominal → vérifier que BAT1 reste déconnectée
|
||
```
|
||
**Pass** : LED rouge fixe, pas de reconnexion quelle que soit la tension.
|
||
**Reset** : power cycle ESP32 (Nb_switch remis à 0 en RAM).
|
||
|
||
---
|
||
|
||
#### TB11 — Test 4 batteries simultanées (F11)
|
||
```
|
||
1. Connecter 4 alimentations sur TCA9535_0 / INA237 0x40–0x43
|
||
2. Vérifier scan I²C : 4 adresses INA + 1 TCA
|
||
3. Mettre BAT3 en sous-tension (22 V)
|
||
4. Vérifier isolation : BAT1, BAT2, BAT4 restent connectées
|
||
```
|
||
**Pass** : seule BAT3 est coupée.
|
||
|
||
---
|
||
|
||
#### TB12 — Log série (F09)
|
||
```
|
||
1. Lancer pio device monitor --baud 115200
|
||
2. Observer les messages pendant les tests TB05–TB11
|
||
```
|
||
**Pass** : messages présents et cohérents avec l'état observé (tension, courant, action).
|
||
|
||
---
|
||
|
||
#### TB13 — Interface web (F10)
|
||
```
|
||
1. Connecter ESP32 au WiFi (ou mode AP)
|
||
2. Ouvrir navigateur → IP de l'ESP32
|
||
3. Vérifier affichage tension/courant en temps réel
|
||
```
|
||
**Pass** : données affichées, rafraîchissement automatique.
|
||
**Priorité** : COULD (optionnel en V1).
|
||
|
||
---
|
||
|
||
## Critères d'acceptance globaux
|
||
|
||
| Critère | Seuil |
|
||
|---------|-------|
|
||
| Couverture MUST (F01–F08, F11) | 100% pass |
|
||
| Couverture SHOULD (F09) | pass ou justification |
|
||
| Couverture COULD (F10) | best effort |
|
||
| Précision mesure tension | ±0.5% pleine échelle |
|
||
| Précision mesure courant | ±5% |
|
||
| Timing coupure | ≤ 1 tick (500 ms) après dépassement seuil |
|
||
| Timing reconnexion temporisée | 10 s ± 1 s |
|
||
| Isolation des coupures (multi-bat) | 0 faux-positif sur batteries saines |
|
||
|
||
---
|
||
|
||
## Ordre d'exécution recommandé
|
||
|
||
```
|
||
L1 ✅ → L2 ✅ → TB01 → TB02 → TB03 → TB04
|
||
↓
|
||
TB13 ← TB12 ← TB11 ← TB10 ← TB09 ← TB08 ← TB07 ← TB06 ← TB05
|
||
```
|
||
|
||
Arrêt sur premier FAIL bloquant (TB01–TB04 sont des prérequis).
|