Pcbnew: Enable some numbering options in pcbnew

The numbering axis priority (h then v or v then h), and alternate
reversing are not actually numbering parameters, they are part of
the geometry of the array (the items are physically in different
orders).

So enable these options, even when numbering is disabled.

Also fix broken logic about when numbering scheme is enabled
(it still applies even if the numbering offset is fixed.)
This commit is contained in:
John Beard
2019-01-30 15:41:35 -08:00
committed by Seth Hillbrand
parent 453a91f661
commit ffaf99a600
4 changed files with 147 additions and 1417 deletions
+13 -15
View File
@@ -318,34 +318,32 @@ void DIALOG_CREATE_ARRAY::setControlEnablement()
{
if ( m_numberingEnabled )
{
const bool renumber = m_rbGridStartNumberingOpt->GetSelection() == 1;
const bool use_set_start_grid = m_rbGridStartNumberingOpt->GetSelection() == 1;
// If we're not renumbering, we can't set the numbering scheme
// or axis numbering types
m_radioBoxGridNumberingScheme->Enable( renumber );
m_labelPriAxisNumbering->Enable( renumber );
m_choicePriAxisNumbering->Enable( renumber );
m_radioBoxGridNumberingScheme->Enable( true );
m_labelPriAxisNumbering->Enable( true );
m_choicePriAxisNumbering->Enable( true );
// Disable the secondary axis numbering option if the
// numbering scheme doesn't have two axes
const bool num2d = m_radioBoxGridNumberingScheme->GetSelection() != 0;
m_labelSecAxisNumbering->Enable( renumber && num2d );
m_choiceSecAxisNumbering->Enable( renumber && num2d );
m_labelSecAxisNumbering->Enable( true && num2d );
m_choiceSecAxisNumbering->Enable( true && num2d );
// We can only set an offset if we renumber
m_labelGridNumberingOffset->Enable( renumber );
m_entryGridPriNumberingOffset->Enable( renumber );
m_entryGridSecNumberingOffset->Enable( renumber && num2d );
// We can only set an offset if we're setting the start number
m_labelGridNumberingOffset->Enable( use_set_start_grid );
m_entryGridPriNumberingOffset->Enable( use_set_start_grid );
m_entryGridSecNumberingOffset->Enable( use_set_start_grid && num2d );
m_entryCircNumberingStart->Enable( m_rbCircStartNumberingOpt->GetSelection() == 1 );
// disable the circular number offset in the same way
const bool use_set_start_circ = m_rbCircStartNumberingOpt->GetSelection() == 1;
m_entryCircNumberingStart->Enable( use_set_start_circ );
}
else
{
// grid
m_rbGridStartNumberingOpt->Enable( false );
m_checkBoxGridReverseNumbering->Enable( false );
m_radioBoxGridNumberingAxis->Enable( false );
m_radioBoxGridNumberingScheme->Enable( false );
m_choiceSecAxisNumbering->Enable( false );
m_choicePriAxisNumbering->Enable( false );