Files
Beaujol-Bus-Lab/20-conception/suivi-poids.md
T
L'électron rare 1456a5ace3 docs: replace weight estimates with datasheet values
Official manufacturer figures for the whole energy chain: US3000C
32.0 kg (bank 128), MultiPlus 30.0, MPPT 4.5, Fronius Primo 21.5
(the one estimate that was off, +5.5 kg), Cerbo ~0.4 (reseller value,
absent from Victron docs), LONGi panel 19.5 confirmed. Weight
tracker, architecture, roof concept and the decision entry all
updated; Fronius MPP window corrected to 80-800 V.
2026-07-09 13:50:09 +02:00

1.8 KiB
Raw Blame History

Suivi de poids — LE document critique du VASP

Règle (cf. CLAUDE.md) : tout ajout > 5 kg s'inscrit ici.

Point zéro

Donnée Valeur Source
PTAC 18 000 kg (prospectus — à confirmer CG F.2) ../00-vehicule/masses-dimensions-c956e.md
Masse max essieu AV 6 500 kg relevé CG/plaque (2026-07-09)
Masse max essieu AR 12 000 kg relevé CG/plaque (2026-07-09)
PV pesé à vide pesée à faire (PV minimal papiers : 11 000 kg) ticket de pesée
Budget masse aménagement PTAC PV marge 10 % PTAC ≈ 5 200 kg (théorique sur PV 11 000, à recaler après pesée) calcul

Registre des masses

Date Poste Domaine Masse (kg) Position (av/ar, G/D) Cumul (kg)
0

Estimations à venir (avant achat)

Poste Estimation (kg)
Isolation + habillage
Parc batteries (4× Pylontech US3000C, soute) 128 (4× 32,0 — datasheet)
Électronique énergie (MultiPlus 30,0 + MPPT 4,5 + Fronius 21,5 + Cerbo ~0,4) ~56 (datasheets — Cerbo : valeur revendeur)
Solaire toit — 20 panneaux LONGi LR4-60HPH-370M (2 étages × 10) 390 (20 × 19,5 — datasheet)
Solaire toit — structure étage fixe (rails alu + pattes) ~75
Solaire toit — étage mobile (cadre alu autoporteur + glissières + verrous) ~180-250 (alu impératif — acier ≈ ×2)
Solaire toit — câblage, chaîne porte-câbles, presse-étoupes ~15
Sous-total toit (~35 kg/m², à 3,3 m de haut → CG +10-12 cm) ~660-730
Eau (pleins) 1 kg/L × volume
Machines (cf. ../60-machines/inventaire.md)
Mobilier + établis
9 sièges + ancrages