8 Commits

Author SHA1 Message Date
L'électron rare 1456a5ace3 docs: replace weight estimates with datasheet values
Official manufacturer figures for the whole energy chain: US3000C
32.0 kg (bank 128), MultiPlus 30.0, MPPT 4.5, Fronius Primo 21.5
(the one estimate that was off, +5.5 kg), Cerbo ~0.4 (reseller value,
absent from Victron docs), LONGi panel 19.5 confirmed. Weight
tracker, architecture, roof concept and the decision entry all
updated; Fronius MPP window corrected to 80-800 V.
2026-07-09 13:50:09 +02:00
L'électron rare 391aeb781d feat: add FreeCAD parametric layout model
Third leg of the CAD tooling: FreeCAD 1.1 for 3D and dimensioned
technical drawings. Seed a spreadsheet-driven model of the interior
(envelope, 9-seat zone, shower cell, Tiroclass bench, fab-machine
zone) so the survey of the emptied bus only has to fill in the
dimension sheet to recalibrate the whole layout. Conventions and
planned files documented in the folder README; decision registered.
2026-07-09 13:02:19 +02:00
L'électron rare b615968e7d docs: adopt QElectroTech for installation diagrams
Split the schematic tooling by audience: QElectroTech (IEC 60617,
versionable XML) for the 48V/230V/PV installation folios that
electricians and inspectors read, KiCad kept for in-house boards
(monitoring, solar-deck interlock). Seed qet/ with the folio plan
and conventions; record the decision.
2026-07-09 12:32:00 +02:00
L'électron rare 22fa5fcf14 docs: apply final review minor fixes 2026-07-09 11:52:01 +02:00
L'électron rare 2f7031cd2d docs: correct battery specs to US3000C 2026-07-09 11:42:21 +02:00
L'électron rare c1d361108d docs: record blog infra decisions
Document the real bus.saillant.cc exposure chain (cloudflared ->
Traefik -> Tower nginx pinned by digest) now that Task 7 hosting
and Task 8 deploy.sh have been validated end-to-end.
2026-07-09 11:36:05 +02:00
L'électron rare 5f0914d2ba docs: record Victron energy architecture 2026-07-09 11:21:10 +02:00
L'électron rare 5e197f0d6b docs: add project root docs 2026-07-09 10:55:28 +02:00